VE4001S3T1B1 | DeltaV™ Discrete Input Card

VE4001S3T1B1 | DeltaV™ Discrete Input Card

Brand: Emerson

Product ID: VE4001S3T1B1

Condition: New / used

Terms of payment: Paypal、T/T 、Western Union

Category:

Description

Serial communication module EIA-232-c (RS-232) module Eia-232 (RS-232) is compatible with single-ended data transmission up to 15 meters (50 feet). Data rate: Baud rate from 300 to 115.2K. Format: Asynchronous, 7-bit or 8-bit (configured by software), with full switching handling. Parity: None, base check, and parity check (software configurable). LED: For COM3 RX(receive) signals and TX(transmit) signals on EIA-232 (RS-232) communication modules. EIA-485-c (RS-485) module It complies with the EIA-485 (RS-485) standard and can transmit differential data up to 1,220 meters (4,000 feet). Data rate: Baud rate from 300 to 115.2K. Format: Asynchronous, 7-bit or 8-bit (configured by software). Parity: None, base check, and parity check (software configurable). LED indicator :A and B indicate the status of communication activity. Function: Activate COM3. If a communication module is installed in slot 2, the COM2 communication port of the CPU is switched to the module in slot 2. Protocol :ROC, Modbus master-slave device (RTU or ASCII). Ability requirements: Large 0.03W, powered by the backplane. Eia-232 (RS-232): Receive 21mw, transmit 50mw. Eia-485 (RS-485): Receives 27mw, transmits 35mw. environment Operating temperature :-40 to 75°C(-40 to 167°F). Storage temperature :-50 to 85°C(-58 to 185°F). Operating humidity: Relative humidity 5% ~ 95%(non-condensing). Dimensions: Height 82.55mm x width 25.4mm x length 127mm (H 3.25 "x W 1.0" x D 5.0 ") Weight :90.7 g (3.2 oz). Wiring: Dimensions 16 to 24 AWG.

公司介绍 (1).png

Product descriptionTraditional I/O subsystems include: I/O interface carrier (surface mounted DIN rail) on which all I/O related components are mounted. ● Provide a large amount of AC to 24V DC power for field equipment. An I/O interface consisting of an I/O card and an I/O terminal block. Various analog and discrete I/O cards are encapsulated in a common form factor that can be easily inserted into their I/O interface carrier. ● Various I/O terminal blocks installed on the I/O interface carrier can be pre-wired before the I/O card is installed I/O card A variety of analog and discrete I/O cards are available to meet your specific requirements. The following cards support simplexor redundancy installation: ● AI 4-20ma HART 8 channel ● AO-4-20 mA HART 8 channel ● DI, 24V DC dry contact, 8 channels ● DO 24V DC High-Side, 8 channels ● AI (Plus) 4-20 mA HART, 16 channels ● AO (Plus) 4-20 mA HART, 16 channels ● DI (Plus) 24V DC, dry contact, 32 channels ● DO (Plus) 24V DC, High-Side, 32 channels The following I/O cards support simplex formats to meet your field wiring needs. ● AI isolation, 4 channels ● RTD, 8 channels ● Thermocouple, 8 channels, millivolts, 8 channels ● DI, high density, 32 channels ● DI 24V DC isolation, 8 channels ● Multi-functional, 4 channels (isolated DI) ● Event sequence, 16 channels (DI 24v DC) ● DI 120V AC low side detection, 8 channels ● DI 120V AC isolation, 8 channels ● DO 24V DC isolation, 8 channels ● DO 120/230V AC high side, 8 channels ● DO 120/230 isolation, 8 channels

微信截图_20240123092325.png

I/O card redundancy Redundant I/O cards can be used for critical applications. The same card can be used for single or redundant applications. When mounted on two wide redundant terminal blocks, the card is recognized as a redundant pair by the controller. The controller scans each card and determines which card is the active interface. When a fault is detected, the system automatically switches to the standby I/O card. The DeltaV control module reference single is the same as the redundant anti /O channel. No special configuration requires redundancy. Switching of redundant I/O cards is done in two scans of the I/O bus. Closing the contact before breaking ensures that the digital field instrument remains powered and the process is not disturbed. The analog output signal is briefly driven by both cards for <5 milliseconds during card switching. Hardware Alerts automatically report hardware integrity errors for both primary and secondary cards. Any events that result in a switch are also automatically reported via system hardware alerts and recorded in the event chronicle. Events that can cause a switch include: ● Hardware failure in the active card. ● Communication between the active card and the controller fails. ● On-site wiring fault detection

公司介绍 (5).png

The company focuses on DCS, PLC, robot, large servo four systems

The main products are various modules/cards, controllers, touch screens, servo drivers Company advantage: Supply imported original products, professional production of spare parts One year warranty, fast delivery time, complete supply !!! ① 24 hours email response (12 hours); ② For shipment outside Asia, please contact the seller.


Emerson Related Products

1C31181G015X00300G01
1C31181G035X00327G01
1C31181G045X00332G01
1C31182G025X00333G01
1C31183G015X00354G01
1C31189G035X00355G01
1C31191G015X00356G01
1C31194G045X00357G01


【 Disclaimer 】 We sell new products and discontinued products, independent channels to buy such special products. Guizhou Yuanmiao Automation Equipment Co., Ltd. is not an authorized distributor, dealer or representative of the products featured on this website. All product names/product images, trademarks, brands and microlabels used on this Website are the property of their respective owners. Descriptions, depictions or sales of products with such names/images, trademarks, brands and logos are for identification purposes only and do not imply any association or authorization with any rights holder. This article is from the official website of Guizhou Yuanmiao Automation Equipment Co., LTD. Please attach this link:http://www.ymdcs.com/EMERSON/

contact us