Description
Features
• 1 Cable entry M 20 x 1.5 • IDC method of termination • Manual release • Thermoplastic enclosure • Double-insulated • Compact design • Interlock with protection against incorrect locking. • Long life • High holding force
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Holding force FZh in accordance with EN ISO 14119 | 1,000 N |
Holding force Fmax, maximum | 1,300 N |
Latching force | 30 N |
Positive break travel | 11 mm |
Positive break force per NC contact, minimum | 8.5 N |
Positive break force, minimum | 17 N |
Actuating speed, maximum | 2 m/s |
Mounting | Screws |
Type of the fixing screws | 2x M5 |
Tightening torque of the fastening screws for the housing cover, minimum | 0.7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum | 1 Nm |
Note | Torx T10 |
Mechanical data - Connection technique
Cable entry | 1 x M20 x 1,5 |
Termination | IDC method of termination |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 1 mm² |
Allowed type of cable | flexible |
Mechanical data - Dimensions
Length of sensor | 30 mm |
Width of sensor | 90 mm |
Height of sensor | 84 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Electrical data
Rated control voltage | 24 VAC/DC |
Required rated short-circuit current | 1,000 A |
Electrical power consumption, maximum | 12 W |
Switching element | 2 NC contact |
Note (Switching element) | Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges |
Switching principle | slow action, positive break NC contact |
Maximale Schalthäufigkeit | 1,000 /h |
Material of the contacts, electrical | Silver |
Electrical data - Magnet control
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 50 ms |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 2.5 A |
Main brands include: ABB, Bailey, GE, FOXBORO, Invensys TRICONEX, Bentley BENTLY, A-B Rockwell, EMERSON EMERSON, B&R, MOTOROLA, FUANC, REXROTH, KUKA, HONEYWELL, NI, DEIF, Yokogawa, WOODWARD WOODWARD, Ryan, SCHNEIDER SCHNEIDER, Yaskawa, MOOG, EPRO, PROSOFT and other major brands
[Disclaimer]
Guizhou Yuanmiao Automation Equipment Co., LTD. We sell new products and discontinued products, independent channels to purchase such special products. Guizhou Yuanmiao Automation Equipment Co., Ltd. is not an authorized distributor, distributor or representative of the featured products on this website. All product names/product images, trademarks, brands and logos used on this website are the property of their respective owners. Descriptions, descriptions or sales of products bearing these names, pictures, trademarks, brands and logos are for identification purposes only and do not imply any association or authorization with any rights holder.